prEN 18228 - Practical Risk Management System Requirements for AI

Draft European Standard - April 2026 | CEN/CENELEC JTC 21 | Fully aligned with EU AI Act Regulation 2024/1689 (Article 9)

Introduction - Why This Matters in Practice

0.1 General | 0.2 Fundamental Rights in Real AI Projects

0.1 General - What You Actually Need to Do

The draft standard (prEN 18228) specifies requirements and provides guidance for a systematic, product-safety-focused risk management system for AI systems. It is designed for providers of high-risk AI systems under the EU AI Act to identify hazards to health, safety and all fundamental rights in the EU Charter, estimate and evaluate risks, control them, and monitor effectiveness throughout the entire life cycle.

Real-world example: A clinical decision-support LLM or a hiring-screening tool must maintain a living Risk Management File that auditors or notified bodies can request at any time. Risk management is iterative and must be integrated into your product realization / quality management system (see prEN 18286).

0.2 Fundamental Rights - How to Protect Them Day-to-Day

Every risk must be explicitly mapped to relevant EU Charter rights (absolute, qualified or privately enforceable). Risk acceptability criteria for qualified rights must consider necessity, proportionality and legitimate objectives. Objective evidence - preferably direct consultation with affected persons and vulnerable groups (including children) - is mandatory.

Practical action: For any AI system, document the exact Charter articles at risk, the severity (including scale, cumulative effects and irremediability), and how you reduced interference to an acceptable level using the strict hierarchy of controls.

1. Scope - What This Means in Practice

Clause Details - How to Apply It

In practice you must:

  • Apply this risk management system to every AI system you place on the market or put into service that falls under the EU AI Act's high-risk categories (Annex III).
  • Cover the full life cycle from inception to end-of-life, including risks to health, safety and fundamental rights.
  • Address reasonably foreseeable misuse, vulnerable groups (especially persons under 18), cyber threats, bias, data quality and adaptiveness.
Example: An energy-grid optimisation AI agent or a warehouse-worker monitoring system must manage both physical safety risks and fundamental-rights risks (data protection, non-discrimination, psychosocial harms).

2. Normative References - Documents You Must Use

Clause Details - What to Do

Indispensable references include:

  • prEN 18229-1 (Logging, transparency and human oversight)
  • prEN 18286 (AI Quality Management System)
  • Regulation (EU) 2024/1689 (EU AI Act) - especially Article 9
  • prEN 18282 (Cybersecurity), prEN 18283 (Bias management), prEN 18284 (Datasets)
  • EU Charter of Fundamental Rights + Annex C guidance
  • EN IEC 31010 (Risk assessment techniques)
Tip: Maintain a living "Standards Map" in your Risk Management File showing how each clause of prEN 18228 satisfies specific AI Act Article 9 requirements (see Annex ZA).

3. Terms and Definitions - Practical Meanings You Use Every Day

Clause Details - Key Terms in Action

Key terms you will use daily:

  • AI system - machine-based system designed to operate with varying levels of autonomy and adaptiveness (AI Act Art. 3(1)).
  • Hazard - potential source of harm (technical or non-technical; AI outputs or decisions can be hazards).
  • Risk scenario - sequence or combination of events/circumstances leading from hazard to harm.
  • Overall residual risk - aggregate of all residual risks (can be unacceptable even if every individual risk is acceptable).
  • Risk Management File - central, traceable repository of all risk documentation.
Example: In a wearable PPE-tracking system, the hazard is "higher false-positive rate for certain workers". The risk scenario is "sensor inaccuracy in specific environments leading to unjustified disciplinary action".

4. Requirements for the Risk Management System (4.1 - 4.6)

4.1 Process | 4.2 Management Responsibilities | 4.3 Competence | 4.4 Acceptability Criteria | 4.5 Plan | 4.6 File

4.1 - 4.6 Core Requirements

The provider shall establish, implement, document and maintain an ongoing risk management system that includes risk analysis, evaluation, testing, control, overall residual risk evaluation, review and pre-/post-market activities. All activities are documented in a single Risk Management File with full traceability via unique hazard IDs.

Management must: Define risk acceptability criteria (each residual risk + overall residual risk) using objective evidence (preferably consultation with affected/vulnerable persons), ensure competent personnel, approve the risk policy and plan, and conduct regular reviews.

Risk acceptability criteria must consider intended purpose, foreseeable misuse, state of the art, alternatives (including non-AI), severity (reversibility, scale, cumulative effects), distribution across groups, and fundamental-rights dimensions.

5. Risk Management Process and AI System Life Cycle

Clause Details - Integration Across the Lifecycle

The risk management process must be applied systematically and iteratively from inception through design, development, deployment, operation and decommissioning. Risk analysis and evaluation begin at the inception stage. New information (testing, post-market data, incidents) can trigger full or partial re-execution.

Practical tip: Earlier mitigation (especially inherently safe design) is far cheaper than later fixes. Document life-cycle stages in the Risk Management File.

6. Risk Analysis - Hazards, Scenarios & Estimation

6.1 General | 6.2 Intended Purpose, Misuse, Characteristics, Hazards | 6.3 Estimation

You must document intended purpose, identify reasonably foreseeable misuse, list all relevant AI system characteristics (outputs, user profiles, autonomy, data sensitivity, cyber vulnerabilities, etc.), then identify hazards, risk scenarios and hazardous situations using multiple techniques (PHA, HAZOP, FTA, STPA, etc.).

For each hazard/hazardous situation, estimate probability of harm (qualitative if quantitative data is unavailable) and severity (nature, reversibility, number of persons affected, specific vulnerabilities, cumulative/long-term effects, fundamental-rights dimensions).

Annex A examples (PPE tracking, clinical LLM, hiring AI, energy-grid agent, warehouse monitoring, etc.) provide ready-to-adapt templates.

7. Risk Evaluation

Clause Details - Decision Point

Compare every estimated risk against the predefined acceptability criteria. Acceptable risks become residual risks. Unacceptable risks must proceed to risk control (Clause 9). Document the reasoning for each risk in the Risk Management File.

8. Testing (incl. Real-World Conditions)

Clause Details - Mandatory Evidence

Testing is required to identify hazards, provide objective evidence of residual and overall risk acceptability, and validate controls. You must have a documented test plan with objectives, methods, acceptance criteria (metrics/probabilistic thresholds), and a test completion report. Real-world conditions testing is mandatory when lab evidence is insufficient (with risk thresholds, consent and monitoring).

Key references: ISO/IEC TR 29119-11 and applicable AI Act sandbox rules.

9. Risk Control - Hierarchy & Implementation

9.1 Hierarchy | 9.2 Implementation & Verification

9.1 Strict Hierarchy of Risk Control

  1. Inherently safe design (preferred - eliminate the hazard or reduce risk as far as technically feasible)
  2. Protective measures / technical guards
  3. Information, instructions for use and training (only as complement - never the sole measure)

9.2 Implementation & Verification

Implement controls at the appropriate life-cycle stage, verify effectiveness (including testing and vulnerable-group-specific methods), evaluate any new hazards introduced, and re-evaluate residual risk. Completeness of risk control must be confirmed.

Example of inherently safe design: An AI benefits calculator that refuses to output any decision if mandatory input data is missing or out of range.

10. Evaluation of Overall Residual Risk

Clause Details - Final Acceptability Check

After all individual risk controls are implemented and verified, evaluate the overall residual risk using the criteria defined in the risk management plan. Even if every individual residual risk is acceptable, the aggregate (interactions between risks, cumulative/long-term harms, distribution across groups, children's best interests) may still be unacceptable.

If the overall residual risk is unacceptable, implement additional controls, modify the intended purpose, or do not deploy the AI system. Significant residual risks must be clearly communicated to deployers in the accompanying documentation.

Practical tip: Use objective evidence from testing and stakeholder consultation. Document the justification for overall acceptability in the Risk Management File.

11. Risk Management Review

Clause Details - Periodic Oversight

The provider must review the execution of the risk management plan periodically (at least prior to placing on the market and after serious incidents or near-misses). The review must confirm that the plan has been implemented, the overall residual risk is acceptable, and appropriate post-market monitoring is in place. Top management must approve the review.

Action required: Document decisions and any modifications to the risk management process in the Risk Management File.

12. Pre-Market and Post-Market Activities

Clause Details - Continuous Monitoring & Response

Establish and maintain a system to actively collect and review relevant information in both pre-market and post-market phases (logs, user feedback, incidents, complaints, state-of-the-art changes). Review this information for new hazards, changed risks, or unacceptable overall residual risk. If risks become unacceptable, reassess, update controls, inform stakeholders, or withdraw the system as necessary. All actions feed into the risk management review and the Risk Management File.

Practical reminder: Post-market data is a required input to the ongoing suitability review of the entire risk management system.
Back to Home